Performance analysis of ground source heat pump system under low load rate

Yangfang Dong, Zhaotian Zeng, Hui Zhu, Yan Liu, Miaomeng Liang

Article ID: 1515
Vol 4, Issue 2, 2021

VIEWS - 576 (Abstract) 751 (pdf)

Abstract


Taking a demonstration project of a ground source heat pump system under karst geological conditions in Guilin as the research object, based on the measured data under operating conditions in a typical season, and sorted according to the importance of influencing factors, this paper mainly studies the influence of system at very low load rate and unit load rate on the operation effect of ground source heat pump system. The research results show that the ground source heat pump system is in good operating condition when the system load rate is lower than 30.00% and the unit load rate is higher than 80.00% in typical seasons, and the proportion of power consumption of units and pumps meets the energy consumption requirements of transmission and distribution system. During the operation of the heat pump unit in July, the average refrigeration performance coefficient of the unit is 4.48, and the average refrigeration energy efficiency ratio of the system is 3.59; during the operation in January, the average heating performance coefficient of the unit is 4.26, and the average heating energy efficiency ratio of the system is 3.32; the energy saving rate in summer and winter is 30.72% and 35.93%, respectively. The energy-saving effect of the ground source heat pump system is remarkable, and it is worth popularizing and applying in Guilin.

Keywords


Ground Source Heat Pump System; System Load Rate; Unit Performance Coefficient; System Energy Efficiency Ratio; Energy Saving rate

Full Text:

pdf


References


1. Li Y, Wang Y. Present situation and trend of ground source heat pump technology in China. Industry Observation 2009; (5): 38–39.

2. Wang L, Gao W. The relationship between groundwater activity and karstic collapse in the western regions of Guilin. Journal of Guilin Institute of Technology 2000; 20(2): 106–111.

3. Dong Y, Wang L, Zeng Z, et al. The research on heat transfer performance of the continuous and intermittent operation condition of ground heat exchangers. Renewable Energy Resources 2014; 32(11): 1687–1693.

4. Zeng Z, Zhao Y, Lyu H, et al. Experimental study on operation modes impact on heat exchange performance of ground heat exchanger. Renewable Energy Resources 2016; 34(5): 737–744.

5. Zeng Z, Lyu H, Zhao Y, et al. Numerical stimulation of effect of ground water seepage on vertically buried tubular heat exchanger. Acta Energiae Solaris Sinica 2015; 36(12): 3007–3014.

6. Guo C, Du Q, Ma J, et al. Research on the influence of ground heat exchanger partition operating on soil heat accumulation. Journal of Thermal Science and Technology 2018; 17(4): 259–266.

7. Wang L, Xu Y. Operating characteristics of ground source heat pump system in non-equilibrium cooling and heating load. Journal of Thermal Science and Technology 2016; 15(2): 154–159.

8. Li H, Xu W, Wu J, et al. Operation performance analysis of ground source heat pump system in certain nearly zero energy building based on actual measurement data. Building Science 2015; 31(6): 124–130.

9. Wang E, Shen Y, Chen Y, et al. Study on the utilization mode of double buried pipe groups of solar-ground source heat pump system. Journal of Thermal Science and Technology 2020; 19(2): 103–109.

10. Yan L, Hu P, Peng B, et al. Research on assessment of ground source heat pump demonstration project in Wuhan. Building Science 2014; 30(12): 25–29.

11. Yan L, Hu P, Li C, et al. The performance prediction of ground source heat pump system based on monitoring data and data mining technology. Energy and Buildings 2016; 127: 1085-1095.

12. Huang X, Liu C. Performance test and analysis of ground source heat pump system based on data mining. Journal of Engineering for Thermal Energy and Power 2020; 35(3): 181–186.

13. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Technical code for ground-source heat pump system. Chinese patent. GB 50366-2009. 2009 Jun 1.

14. Ministry of Housing and Urban-Rural Development of the People’s Republic of China. Evaluation standard for application of renewable energy in buildings. Chinese patent. GB/T50801-2013. 2013 May 1.

15. Department of Housing and Urban-Rural Development of Guangxi Zhuang Autonomous Region. Guidelines for energy efficiency evaluation of renewable energy technology application in civil buildings in Guangxi. Available from: https://www.taodocs.com/p364030473.html.

16. Zhu L, Shi Y, Zhang X, et al. Analysis of operation strategies of residential Hybrid ground-coupled heat pump system on different occupancy rate. Fluid Machinery 2016; 44(3): 76–79.

17. Xu W. Research report on ground-source heat pump development in China. Beijing: China Construction Industry Press; 2013.

18. Zeng Z, Zhao Y, Lv H, et al. Heat and moisture migration in soils around ground heat exchangers under heating operation of ground source heat pump. Chinese Journal of Geotechnical Engineering 2017; 39(1): 145–150.




DOI: https://doi.org/10.24294/tse.v4i2.1515