Application of infrared thermography in radiation protection and other medical fields

Zhen Yao, Minyan Zhao, Yulong Liu

Article ID: 1740
Vol 4, Issue 1, 2021

VIEWS - 619 (Abstract) 523 (PDF)

Abstract


Infrared thermal imaging technology is another new branch for medical imaging after traditional medical imaging technologies such as X-ray, ultrasound and magnetic resonance (MRI). It has the advantages of noninvasive, nondestructive, simple and fast. Its application can radiate multiple clinical departments. This paper mainly expounds the principle, influencing factors of medical infrared thermography and its application in radiation protection and other medical fields.


Keywords


Infrared Thermography; Radiation Protection; Principle; Influencing Factors; Clinical Application

Full Text:

PDF


References


1. Ring F, Jung A, Zuber J. New opportunities for infrared thermography in medicine. Acta Bio-Optika et Informatica Medica 2009; 15(1): 28–30.

2. Lv S, Wang Y, Li H, et al. The significance and principle of infrared thermal radiation of the human body. Chinese Journal of Current Praticle Medicine 2004; 3(1): 33–34.

3. Ammer K. Temperature gradients in Raynaud’s phenomenon. Comparison by gender, age class and finger involvement. Thermology International 2010; 20(3): 100–109.

4. Wen J, Zheng C, Li S. The application of infrared radiation in medicine. Foreign Medical Sciences Section of Radiation Medicine and Nuclear Medicine 2004; 28(5): 237–240.

5. Wei Z, Tong M. Yiyong hongwai rexiang zhenduan zhong de shengwu he wuli jili (Chinese) [The biological and physical mechanism of infrared thermal imaging in medical diagnosis]. Life Science Instruments 2005; 3(2): 20–22.

6. Zhang R, Zhu S, Qu Q, et al. Research progress of infrared thermal imaging technology in western medical filed. China Health Industry 2019; 16(04): 197–198.

7. Godoy SE, Hayat MM, Ramirez DA, et al. Detection theory for accurate and non-invasive skin cancer diagnosis using dynamic thermal imaging. Biomedical Optics Express 2017; 8(4): 2301–2323.

8. Yuan Y. Medical digital infrared thermal imaging technology introduction. Zhengzhou: Zhengzhou University Press; 2013.

9. Namkoong S, Shim JM, Kim SJ, et al. Effects of different sitting positions on skin temperature of the lower extremity. Journal of Physical Therapy Science 2015; 27(8): 2637–2640.

10. International Atomic Energy Agency (IAEA). Diagnosis and treatment of radiation injuries. Vienna: IAEA; 1998.

11. Liu Y, Wang Y, Yu D, et al. Medical management of the victim exposed to 192Ir source at “5.7” accident in Nanjing. Chinese Journal of Radiological Medicine and Protection 2016; 36(5): 324–330.

12. Lawson R. Implications of surface temperatures in the diagnosis of breast cancer. Canadian Medical Association Journal 1956; 75(4): 309–310.

13. Williams KI, Williams FJ, Handley RS. Infra-red thernometry in the diagnosis of breast cancer. The International Journal of Cancer 1961; 2(7217): 1378–1381.

14. Ng EYK. A review of thermography as promising non-invasive detection modality for breast tumor. International Journal of Thermal Sciences 2009; 48(5): 849–859.

15. Xiao Y, Lu Z, SiTu J. Hongwai rechengxiangtu faxian dishenjing qiaoliu 1 li (Chinese) [A case of sacral schwannoma was found by infrared thermal imaging]. Chinese Journal of Pain Medicine 2018; 24(9): 718–720.

16. Wand P, Zhang Q, Ruan J, et al. Hongwai rexiangtu zhenduan jiazhuangxianai de tantao (Chinese) [Discussion on the diagnosis of thyroid cancer by infrared thermography]. Chinese Journal of Medical Imaging Technology 1997; (6): 510–511.

17. Lu G, Pang W, Wang L. The application of diagnosis in the Nessopharyngel Cancer (NPC) by infrared imaging system. Laser & Infrared 2001; 31(1): 42–44.

18. Liu J, Yang M, Sun C. Weibo jiare timo, hongwairechengxiang cewen guancha—Fu 9 li kouqiangai weibo reliao linchaung (Chinese) [Microwave heated bulk mode, infrared thermal phase temperature observation—Microwave hyperthermia of 9 cases of oral cancer was reported]. Stomatology 1992; (2): 78–80.

19. Huang X, Yang C, Wu X, et al. Hongwai rexiangshu yongyu houbu zhongliu ji jingbu zhongkuai zhenduan de tantao (Chinese) [The application of external thermal imaging in the diagnosis of laryngeal tumors and neck tumors]. Journal of Clinical Otorhinolaryngology. Head and Neck Surgery 1990; (1): 1–3.

20. Darton K, Black CM. Pyroelectric vidicon thermographyand cold challenge quantify the severity ofraynaud’s phenomenon. Rheumatology 1991; 30(3): 190–195.

21. Caramaschi P, Codella O, Poli G, et al. Use of computerized digital thermometry for diagnosis ofraynaud’s phenomenon. Angiology 1989; 40(10): 863–871.

22. Ammer K. Diagnosis of Raynaud’s phenomenon by thermography. Skin Research and Technology 1996; 2(4): 182–185.

23. Cherkas LF, Carter L, Spector TD, et al. Use of thermographic criteria to identify Raynaud’s phenomenon in a population setting. The Journal of Rheumatology 2003; 30(4): 720–722.

24. Aronen HJ, Suoranta HT, Taavitsainen MJ. Thermography in deep venous thrombosis of the leg. American Journal of Roentgenology 1981; 137(6): 1179–1182.

25. Armstrong DG, Lipsky BA, Polis AB, et al. Does dermal thermometrypredict clinical outcome in diabetic foot infection? Analysis of data from the SIDESTEP* trial. International Wound Journal 2006; 3(4): 302–307.

26. Yao W, Xue Y, Luo Y, et al. Using infrared thermography to diagnose ischemic cerebrovascular disease and evaluate its treatment effect. Chinese Journal of Laser Medicine & Surgery 2007; 16(2): 99–103.

27. Liu W, Sun G, Jia W, et al. Analysis of the characteristics of infrared imaging in pre-hypertension patients. Journal of Hunan University of Chinese Medicine 2016; 36(9): 86–89.

28. Li Q, Li K, Fan H, et al. Infrared thermo-imaging inspection in coronary artery disease. Chinese Journal of Medical Imaging Technology 2008; (S1): 205–207.

29. Su P, Huang D, Xiong C. The diagnostic value of infrared thermography in pelvic inflammatory disease. Chinese Journal of Physical Medicine and Rehabilitation 2004; 26(3): 183–185.

30. Ring EFJ, Ammer K. Infrared thermal imaging in medicine. Physiological Measurment 2012; 33(3): 33–46.

31. Cheng C. Application of medical far infrared thermography technology in neurosurgery [Master’s thesis]. Beijing: Chinese PLA General Hospital & Medical School; 2014.

32. Esselinckx W, Bacon PA, Ring EF, et al. A thermographic assessment of three intra-aricular prednisolone analogues given in rheumatoid synovitis. British Journal of Clinical Pharmacology 1978; 5(5): 447–451.

33. Lambiris E, Stoboy H. Thermography in osteosyntheses and total endoprostheses of the knee joint with and without infection. Zeitschrift fur Orthopadie und ihre Grenzgebiete 1981; 119(5): 521–524.

34. Baic A, Kasprzyk T, Rzany M, et al. Can we use thermal imaging to evaluate the effects of carpal tunnel syndrome surgical decompression. Medicine 2017; 96(39): e7982.

35. Fang Z, Shu F, Yuan S, et al. Hongwai rechengxiang jishu zai linchuang tengtong pingding biaozhun zhong de yingyong jinzhang (Chinese) [Advances in the application of infrared thermal imaging in clinical pain assessment criteria]. Chinese Journal of Medical Imaging 2011; 19(12): 931–934.

36. Yin X, Chen Q. Hongwai rechengxiang jishu zai zhongyi bianzheng ji bianbing zhong de yingyong xianzhuang gaishu (Chinese) [An overview of the application of infrared thermal imaging in TCM syndrome differentiation and disease differentiation]. Asia-Pacific Traditional Medicine 2018; 14(12): 80–82.

37. Yi T, Han Z, Ji Z, et al. Application of infrared thermal imaging in disease prevention. Infrared 2018; 39(11): 39–43.

38. Du X, Li Y, Zhou X, et al. Hongwai rechengxiang jishu zai zhenjiu lingyu de yingyong (Chinese) [Application of infrared thermal imaging in acupuncture research field]. Journal of Hebei Traditional Chinese Medicine and Pharmacology 2018; 33(1): 60–64.

39. Wang Y. Qingnianren tanshizhi yu pinghezhi rejiegou duibixing yanjiu (Chinese) [Comparative study on phlegm-dampness and phlegm-heat structure in young people] [Master’s thesis]. Beijing: Beijing University of Chinese Medicine; 2018.




DOI: https://doi.org/10.24294/irr.v4i1.1740

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Creative Commons License

This site is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.