Energy saving analysis of photovoltaic roof based on MATLAB
Vol 5, Issue 2, 2022
VIEWS - 473 (Abstract) 315 (pdf)
Abstract
One-dimensional unsteady theoretical models of three different photovoltaic module installation modes are established. Through MATLAB modeling and simulation, the influence of photovoltaic modules on roof heat transfer in different layout modes is compared. Comparing with ordinary roof, the shading effect of photovoltaic roof in summer and heat preservation effect in winter was analyzed. The results show that the PV roof layout with ventilation channel is better in summer. The proof layout with closed flow channel is better in winter.
Keywords
Full Text:
pdfReferences
1. Li Z. Guanyu taiyangneng guangfu faduan jishu yu jianzhu shigong de yitihua sheji yanjiu (Chinese) [Research on integrated design of solar photovoltaic power generation technology and building construction]. Low Carbon World 2020; 10(11): 84–86.
2. Brinkworth BJ, Cross BM, Marshall RH, et al. Thermal regulation of photovoltaic cladding. Solar Energy 1997; 61(3): 169–178.
3. Yang H, Zhu Z, Burnett J, et al. A simulation study on the energy performance of photovoltaic roofs. ASHRAE Transactions 2001; 107(2): 129–135.
4. Ji J, He W, Lam HN. The annual analysis of the power output and heat gain of a PV-wall with different integration mode in Hong Kong. Solar Energy Materials and Solar Cells 2002; 71(4): 435–448.
5. Yutaka G, Masako I, Yukitaka O, et al. Impacts of largescale photovoltaic panel installation on the heat island effect in Tokyo. Poland (Lodz): Fifth International Conference on Urban Climate. 2003. p. 181–184.
6. Ren J, LI Z, Wang Y, et al. Interaction between solar PV roofs and loads of the building. Acta Energiae Solaris Sinica 2008; 29(7): 849–855.
7. McClellan TM, Pedersen CO. Investigation of outside heat balance models for use in a heat balance cooling load calculation procedure. ASHRAE Transactions 1997; 103(2): 469–484.
8. Duffie JA, Beckman WA. Solar engineering of thermal processes. Hoboken: Wiley-Interscience; 2006.
9. Brinkworth BJ, Marshall RH, Ibarahim Z. A validated model of naturally ventilated PV cladding. Solar Energy 2000; 69(1): 67–81.
10. Lee WM, Infield DG, Gottschalg R. Thermal modelling of building integrated PV systems. REMIC 2001; Belfast. 2001.
11. Afonso C, Oliveira A. Solar chimneys: Simulation and experiment. Energy & Buildings 2000; 32(1): 71–79.
12. Hollands KGT, Unny TE, Raithby GD, et al. Free convective heat transfer across inclined air layers. Trans of ASME Journal of Heat Transfer 1976; 98(2): 189–193.
13. Yu C. Rechuandao jiqi shuzhi fenxi (Chinese) [Heat conduction and numerical analysis]. Beijing: Tsinghua University Press; 1981.
14. Shampine LF, Reichelt MW. The MATLAB ODE suite. Siam Journal on Scientific Computing 1997; 18(1): 1–22.
15. Magrab EB, Azarm S, Balachandran B, et al. An Engineers Guide to MATLAB. In: Gao H, Li X, Hu Z (translators). Beijing: Publishing House of Electronics Industry; 2002.
DOI: https://doi.org/10.24294/tse.v5i2.1533
Refbacks
- There are currently no refbacks.
Copyright (c) 2022 Hui Luo, Kequn Li
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
This site is licensed under a Creative Commons Attribution 4.0 International License.